Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Pediatr Radiol ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38641735

RESUMO

BACKGROUND: The use of contrast-enhanced imaging has long been standard for magnetic resonance imaging (MRI) assessments of synovitis in juvenile idiopathic arthritis (JIA). However, advancements in MRI technology have allowed for reliable identification of synovium without contrast. OBJECTIVE: To assess the equivalence of unenhanced MRI with contrast-enhanced MRI in evaluating synovial thickness. MATERIALS AND METHODS: This is an institutional review board approved, retrospective study performed in a tertiary children's hospital. Pediatric JIA patients under 21 years old were included who underwent knee MRI scans (1.5 T or 3 T) without and with contrast between January 2012 and January 2022. Two radiologists independently measured synovial thickness at 6 knee sites on contrast-enhanced and unenhanced sequences. Numerical measurements and ordinal scores based on juvenile idiopathic arthritis magnetic resonance imaging scoring (JAMRIS) system were recorded, and tests of equivalence were conducted, as well as between-reader and within-reader reliability by concordance correlation coefficient (CCC). All tests were considered significant at the 5% level. RESULTS: A total of 38 studies from 35 patients (25 females, median age 14 years; interquartile range 7 to 15.7) were included. Equivalence was demonstrated at each of the 6 sites for both continuous measurements (P-values < 0.05) and ordinal scores (P-values < 0.05) based on the average over readers. Within-reader reliability was moderate to high (CCC 0.50-0.89), except for the cruciate ligaments site. Averaged over the 6 sites, reliability between readers was low for unenhanced (CCC 0.47, with 95% CI: [0.41, 0.53]) and moderate for contrast-enhanced (CCC 0.64, with 95% CI: [0.59, 0.69]) sequences. CONCLUSION: Unenhanced knee MRI is equivalent to contrast-enhanced MRI in assessment of synovial thickness using conventional MRI sequences. Contrast material helped improve inter-reader reliability.

2.
Pediatr Radiol ; 54(5): 743-757, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38421417

RESUMO

BACKGROUND: MRI-based synthetic CT (sCT) generates CT-like images from MRI data. OBJECTIVE: To evaluate equivalence, inter- and intraobserver reliability, and image quality of sCT compared to conventional (cCT) for assessing hip morphology and maturity in pediatric patients. MATERIALS AND METHODS: We prospectively enrolled patients <21 years old with cCT and 3T MRI of the hips/pelvis. A dual-echo gradient-echo sequence was used to generate sCT via a commercially available post-processing software (BoneMRI v1.5 research version, MRIguidance BV, Utrecht, NL). Two pediatric musculoskeletal radiologists measured seven morphologic hip parameters. 3D surface distances between cCT and sCT were computed. Physeal status was established at seven locations with cCT as reference standard. Images were qualitatively scored on a 5-point Likert scale regarding diagnostic quality, signal-to-noise ratio, clarity of bony margin, corticomedullary differentiation, and presence and severity of artifacts. Quantitative evaluation of Hounsfield units (HU) was performed in bone, muscle, and fat tissue. Inter- and intraobserver reliability were measured by intraclass correlation coefficients. The cCT-to-sCT intermodal agreement was assessed via Bland-Altman analysis. The equivalence between modalities was tested using paired two one-sided tests. The quality parameter scores of each imaging modality were compared via Wilcoxon signed-rank test. For tissue-specific HU measurements, mean absolute error and mean percentage error values were calculated using the cCT as the reference standard. RESULTS: Thirty-eight hips in 19 patients were included (16.6 ± 3 years, range 9.9-20.9; male = 5). cCT- and sCT-based morphologic measurements demonstrated good to excellent inter- and intraobserver correlation (0.77

Assuntos
Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X , Humanos , Masculino , Criança , Feminino , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Reprodutibilidade dos Testes , Adolescente , Tomografia Computadorizada por Raios X/métodos , Articulação do Quadril/diagnóstico por imagem , Pré-Escolar , Imageamento Tridimensional/métodos
3.
Radiology ; 310(2): e230628, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38411515

RESUMO

HISTORY: A 15-year-old boy presented with a 3-week history of inner left thigh pain provoked by activity and experienced occasionally at rest. He denied nighttime pain, fever, or chills. Laboratory investigation revealed the following normal values: hemoglobin level of 15.6 g/dL (normal range, 13-16 g/dL), platelet count of 240 × 103/µL (normal range, 140-440 × 103/µL), and total leukocyte count of 7100 cells/µL (normal range, 4500-11 000 cells/µL). The percentage of neutrophils was considered low at 44% (normal range, 54%-62%), and the percentage of eosinophils was slightly high at 3.7% (normal range, 0%-3%). An anteroposterior radiograph of the left hip is shown (Fig 1). Physical therapy was initiated, with no improvement after 2 weeks of therapy. The patient was referred to an orthopedist for further evaluation. On physical examination, the patient endorsed marked left hip pain with hip flexion to 90°, limited internal and external rotation (5° and 15°, respectively), and antalgic gait favoring the left leg. Hip MRI (Fig 2) and further serologic analysis were requested for further evaluation. Although the serologic testing was performed at an outside laboratory, the physician reported positive immunoglobulin-G Lyme titers, normal C-reactive protein level, and normal erythrocyte sedimentation rate. Pelvic CT was requested (Fig 3). The patient was prescribed a course of doxycycline (100 mg twice daily for 28 days), with reported resolution of symptoms 2 weeks after initiation of treatment. Three weeks later, he presented to our department with recurrent left hip pain, which was similar in severity compared with initial presentation. A second MRI of the left hip was performed 4 months after initial presentation (Fig 4).


Assuntos
Artralgia , Dor , Masculino , Humanos , Adolescente , Cognição , Doxiciclina , Febre
7.
J Bone Joint Surg Am ; 106(2): 110-119, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-37992184

RESUMO

BACKGROUND: There is limited evidence supporting the value of morphological parameters on post-reduction magnetic resonance imaging (MRI) to predict long-term residual acetabular dysplasia (RAD) after closed or open reduction for the treatment of developmental dysplasia of the hip (DDH). METHODS: We performed a retrospective study of 42 patients (47 hips) undergoing open or closed reduction with a minimum 10 years of follow-up; 39 (83%) of the hips were in female patients, and the median age at reduction was 6.3 months (interquartile range [IQR], 3.3 to 8.9 months). RAD was defined as additional surgery with an acetabular index >2 standard deviations above the age- and sex-specific population-based mean value or Severin classification grade of >2 at last follow-up. Acetabular version and depth-width ratio, coronal and axial femoroacetabular distance, cartilaginous and osseous acetabular indices, transverse ligament thickness, and the thickness of the medial and lateral (limbus) acetabular cartilage were measured on post-reduction MRI. RESULTS: At the time of final follow-up, 24 (51%) of the hips had no RAD; 23 (49%) reached a failure end point at a median of 11.4 years (IQR, 7.6 to 15.4 years). Most post-reduction MRI measurements, with the exception of the cartilaginous acetabular index, revealed a significant distinction between the group with RAD and the group with no RAD when mean values were compared. The coronal femoroacetabular distance (area under the receiver operating characteristic curve [AUC], 0.95; 95% confidence interval [CI], 0.90 to 1.00), with a 5-mm cutoff, and limbus thickness (AUC, 0.91; 95% CI, 0.83 to 0.99), with a 4-mm cutoff, had the highest discriminatory ability. A 5-mm cutoff for the coronal femoroacetabular distance produced 96% sensitivity (95% CI, 78% to 100%), 83% specificity (95% CI, 63% to 95%), 85% positive predictive value (95% CI, 65% to 96%), and 95% negative predictive value (95% CI, 76% to 100%). A 4-mm cutoff for limbus thickness had 96% sensitivity (95% CI, 78% to 100%), 63% specificity (95% CI, 41% to 81%), 71% positive predictive value (95% CI, 52% to 86%), and 94% negative predictive value (95% CI, 70% to 100%). CONCLUSIONS: Coronal femoroacetabular distance, a quantitative metric assessing a reduction's concentricity, and limbus thickness, a quantitative metric assessing the acetabulum's cartilaginous component, help to predict hips that will have RAD in the long term after closed or open reduction. LEVEL OF EVIDENCE: Diagnostic Level IV . See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Luxação Congênita de Quadril , Luxação do Quadril , Masculino , Humanos , Feminino , Lactente , Estudos Retrospectivos , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/patologia , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/cirurgia , Imageamento por Ressonância Magnética , Cartilagem , Luxação do Quadril/patologia , Articulação do Quadril , Resultado do Tratamento
8.
Radiographics ; 43(12): e230076, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37943700

RESUMO

Normal variants and abnormalities of the ribs are frequently encountered on chest radiographs. Accurate identification of normal variants is crucial to avoid unnecessary investigations. A meticulous evaluation of rib abnormalities can provide valuable insights into the patient's symptoms, and even when no osseous condition is suspected, rib abnormalities may offer critical clues to underlying conditions. Rib abnormalities are associated with various conditions, including benign tumors, malignant tumors, infectious and inflammatory conditions, vascular abnormalities, metabolic disorders, nonaccidental injuries, malformation syndromes, and bone dysplasias. Abnormalities of the ribs are classified into three groups based on their radiographic patterns: focal, multifocal, and diffuse changes. Focal lesions are further subdivided into nonaggressive lesions, aggressive lesions, and infectious and inflammatory disorders. Radiologists should be aware of individual disorders of the pediatric ribs, including their imaging findings, relevant clinical information, and underlying pathogenesis. Differential diagnoses are addressed as appropriate. Since chest radiographs can suffice for diagnosis in certain cases, the authors emphasize a pattern recognition approach to radiographic interpretation. However, additional cross-sectional imaging may be necessary for focal lesions such as tumors or inflammatory conditions. Awareness of disease-specific imaging findings helps ascertain the nature of the lesion and directs appropriate management. ©RSNA, 2023 Quiz questions for this article are available in the supplemental material.


Assuntos
Costelas , Humanos , Criança , Radiografia , Costelas/diagnóstico por imagem , Costelas/anormalidades , Costelas/lesões , Diagnóstico Diferencial
9.
Pediatr Radiol ; 53(12): 2411-2423, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37740782

RESUMO

BACKGROUND: Quantifying femoral version is crucial in diagnosing femoral version abnormalities and for accurate pre-surgical planning. There are numerous methods for measuring femoral version, however, reliability studies for most of these methods excluded children with hip deformities. OBJECTIVE: To propose a method of measuring femoral version based on a virtual 3D femur model, and systematically compare its reliability to the widely used Murphy's 2D axial slice technique. MATERIALS AND METHODS: We searched our imaging database to identify hip/femur CTs performed on children (<18 years old) with a clinical indication of femoral version measurement (September 2021-August 2022). Exclusion criteria were prior hip surgery, and inadequate image quality or field-of-view. Two blinded radiologists independently measured femoral version using the virtual 3D femur model and Murphy's 2D axial slice method. To assess intrareader variability, we randomly selected 20% of the study sample for re-measurements by the two radiologists >2 weeks later. We analyzed the reliability and correlation of these techniques via intraclass correlation coefficient (ICC), Bland-Altman analysis, and deformity subgroup analysis. RESULTS: Our study sample consisted of 142 femurs from 71 patients (10.6±4.4 years, male=31). Intra- and inter-reader correlations for both techniques were excellent (ICC≥0.91). However, Bland-Altman analysis revealed that the standard deviation (SD) of the absolute difference between the two radiologists for the Murphy method (mean 13.7°) was larger than that of the 3D femur model technique (mean 4.8°), indicating higher reader variability. In femurs with hip flexion deformity, the SD of the absolute difference for the Murphy technique was 17°, compared to 6.5° for the 3D femur model technique. In femurs with apparent coxa valga deformity, the SD of the absolute difference for the Murphy technique was 10.4°, compared to 5.2° for the 3D femur model technique. CONCLUSION: The 3D femur model technique is more reliable than the Murphy's 2D axial slice technique in measuring femoral version, especially in children with hip flexion and apparent coxa valga deformities.


Assuntos
Coxa Valga , Criança , Humanos , Masculino , Adolescente , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Fêmur/diagnóstico por imagem , Extremidade Inferior , Imageamento Tridimensional/métodos
10.
JBJS Case Connect ; 13(3)2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37418570

RESUMO

CASE: An adolescent female dancer with excessive femoral anteversion presented with posterior and anterior hip pain aggravated by poses that required extension and external rotation. Imaging revealed an atypical cam deformity of the posterior head-neck junction. During surgery, the posterior head-neck junction was observed to impinge on the posterior acetabulum with anterior subluxation of the hip. After a derotational femoral osteotomy, the patient experienced resolution of her symptoms. CONCLUSION: Excessive femoral anteversion can lead to reactive cam deformity, posterior intra-articular impingement, and anterior hip instability in patients who require repetitive hip extension and external rotation, such as ballet dancers.


Assuntos
Impacto Femoroacetabular , Adolescente , Humanos , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Tomografia Computadorizada por Raios X , Amplitude de Movimento Articular , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/cirurgia
11.
J Child Orthop ; 17(2): 86-96, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37034197

RESUMO

Purpose: The purpose of the study was to compare the post-reduction magnetic resonance imaging morphology for hips that developed residual acetabular dysplasia, hips without residual dysplasia, and uninvolved contralateral hips in patients with unilateral developmental dysplasia of the hip undergoing closed or open reduction and had a minimum 10-year follow-up. Methods: Retrospective study of patients with unilateral dysplasia of the hip who underwent open/closed hip reduction followed by post-reduction magnetic resonance imaging. Twenty-eight patients with a mean follow-up of 13 ± 3 years were included. In the treated hips, residual dysplasia was defined as subsequent surgery for residual acetabular dysplasia or for Severin grade > 2 at latest follow-up. On post-reduction, magnetic resonance imaging measurements were performed by two readers and compared between the hips with/without residual dysplasia and the contralateral uninvolved side. Magnetic resonance imaging measurements included acetabular version, coronal/ axial femoroacetabular distance, acetabular depth-width ratio, osseous/cartilaginous acetabular indices, and medial/lateral (limbus) cartilage thickness. Results: Fifteen (54%) and 13 (46%) hips were allocated to the "no residual dysplasia" group and to the "residual dysplasia" group, respectively. All eight magnetic resonance imaging parameters differed between hips with residual dysplasia and contralateral uninvolved hips (all p < 0.05). Six of eight parameters differed (all p < 0.05) between hips with and without residual dysplasia. Among these, increased limbus thickness had the largest effect (odds ratio = 12.5; p < 0.001) for increased likelihood of residual dysplasia. Conclusions: We identified acetabular morphology and reduction quality parameters that can be reliably measured on the post-reduction magnetic resonance imaging to facilitate the differentiation between hips that develop with/without residual acetabular dysplasia at 10 years postoperatively. Level of evidence: level III, prognostic case-control study.

12.
Pediatr Radiol ; 51(9): 1645-1653, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33830291

RESUMO

BACKGROUND: There is a strong need for improvements in motion robust T1-weighted abdominal imaging sequences in children to enable high-quality, free-breathing imaging. OBJECTIVE: To compare imaging time and quality of a radial stack-of-stars, free-breathing T1-weighted gradient echo acquisition (volumetric interpolated breath-hold examination [VIBE]) three-dimensional (3-D) Dixon sequence in sedated pediatric patients undergoing abdominal magnetic resonance imaging (MRI) against conventional Cartesian T1-weighed sequences. MATERIALS AND METHODS: This study was approved by the institutional review board with informed consent obtained from all subjects. Study subjects included 31 pediatric patients (19 male, 12 female; median age: 5 years; interquartile range: 5 years) undergoing abdominal MRI at 3 tesla with a free-breathing T1-weighted radial stack-of-stars 3-D VIBE Dixon prototype sequence, StarVIBE Dixon (radial technique), between October 2018 and June 2019 with previous abdominal MR imaging using conventional Cartesian T1-weighed imaging (traditional technique). MRI component times were recorded as well as the total number of non-contrast T1-weighted sequences. Two radiologists independently rated images for quality using a scale from 1 to 5 according to the following metrics: overall image quality, hepatic edge sharpness, hepatic vessel clarity and respiratory motion robustness. Scores were compared between the groups. RESULTS: Mean T1-weighted imaging times for all subjects were 3.63 min for radial exams and 8.01 min for traditional exams (P<0.001), and total non-contrast imaging time was 32.7 min vs. 43.9 min (P=0.002). Adjusted mean total MRI time for all subjects was 60.2 min for radial exams and 65.7 min for traditional exams (P=0.387). The mean number of non-contrast T1-weighted sequences performed in radial MRI exams was 1.0 compared to 1.9 (range: 0-6) in traditional exams (P<0.001). StarVIBE Dixon outperformed Cartesian methods in all quality metrics. The mean overall image quality (scale 1-5) was 3.95 for radial exams and 3.31 for traditional exams (P<0.001). CONCLUSION: Radial stack-of-stars 3-D VIBE Dixon during free-breathing abdominal MRI in pediatric patients offers improved image quality compared to Cartesian T1-weighted imaging techniques with decreased T1-weighted and total non-contrast imaging time. This has important implications for children undergoing sedation for imaging.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Abdome/diagnóstico por imagem , Artefatos , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Aumento da Imagem , Masculino , Movimento (Física) , Respiração
13.
Skeletal Radiol ; 50(10): 2091-2102, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33797565

RESUMO

OBJECTIVE: To assess the degree of narrowing of the popliteal artery during active ankle plantar flexion in healthy volunteers using a non-contrast quiescent-interval single-shot (QISS) magnetic resonance angiography (MRA) technique. MATERIALS AND METHODS: Following IRB approval, 10 healthy volunteers were recruited and following informed consent underwent QISS MRA of the lower extremity at rest and during ankle plantarflexion. Two pediatric musculoskeletal radiologists independently reviewed MR images in random order and recorded a number of subjective and objective anatomic variables including branch pattern, proximity of vessel to bony structures, gastrocnemius bulk, and presence of accessory muscle. Arterial narrowing with plantarflexion was recorded by a subjective assessment of 3D reconstructions (negligible or non-negligible) and objectively by measuring the narrowest diameter during plantarflexion and at rest. Agreement between reader scores was assessed using the concordance correlation coefficient (CCC) for continuous variables, and kappa and the proportion of agreement for categorical variables. RESULTS: Mean reduction in arterial diameter during plantar flexion was 17.1% (min 1.9%, max 64.1%, SD 16.7%) for reader 1 and 17.2% (min 1.7%, max 50.0%, SD 14.3%.) for reader 2 with high agreement between readers: CCC = 0.92 and CI = 0.82, 0.96. Arterial narrowing was described subjectively as "non-negligible" in 7/20 legs by reader 1 and 5/20 legs by reader 2 with proportion of agreement = 0.90, CI (0.77, 1.00). CONCLUSION: We observed a wide range of popliteal arterial narrowing with plantarflexion in asymptomatic volunteers. Larger studies, for which QISS is well suited, may be invaluable for distinguishing physiologic from pathologic arterial narrowing in patients with suspected popliteal artery entrapment syndrome (PAES).


Assuntos
Doença Arterial Periférica , Síndrome do Aprisionamento da Artéria Poplítea , Tornozelo , Criança , Voluntários Saudáveis , Humanos , Angiografia por Ressonância Magnética , Artéria Poplítea/diagnóstico por imagem , Reprodutibilidade dos Testes
14.
Radiology ; 299(1): 150-158, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33620288

RESUMO

Background Often used for T1 mapping of hip cartilage, three-dimensional (3D) dual-flip-angle (DFA) techniques are highly sensitive to flip angle variations related to B1 inhomogeneities. The authors hypothesized that 3D magnetization-prepared 2 rapid gradient-echo (MP2RAGE) MRI would help provide more accurate T1 mapping of hip cartilage at 3.0 T than would 3D DFA techniques. Purpose To compare 3D MP2RAGE MRI with 3D DFA techniques using two-dimensional (2D) inversion recovery T1 mapping as a standard of reference for hip cartilage T1 mapping in phantoms, healthy volunteers, and participants with hip pain. Materials and Methods T1 mapping at 3.0 T was performed in phantoms and in healthy volunteers using 3D MP2RAGE MRI and 3D DFA techniques with B1 field mapping for flip angle correction. Participants with hip pain prospectively (July 2019-January 2020) underwent indirect MR arthrography (with intravenous administration of 0.2 mmol/kg of gadoterate meglumine), including 3D MP2RAGE MRI. A 2D inversion recovery-based sequence served as a T1 reference in phantoms and in participants with hip pain. In healthy volunteers, cartilage T1 was compared between 3D MP2RAGE MRI and 3D DFA techniques. Paired t tests and Bland-Altman analysis were performed. Results Eleven phantoms, 10 healthy volunteers (median age, 27 years; range, 26-30 years; five men), and 20 participants with hip pain (mean age, 34 years ± 10 [standard deviation]; 17 women) were evaluated. In phantoms, T1 bias from 2D inversion recovery was lower for 3D MP2RAGE MRI than for 3D DFA techniques (mean, 3 msec ± 11 vs 253 msec ± 85; P < .001), and, unlike 3D DFA techniques, the deviation found with MP2RAGE MRI did not correlate with increasing B1 deviation. In healthy volunteers, regional cartilage T1 difference (109 msec ± 163; P = .008) was observed only for the 3D DFA technique. In participants with hip pain, the mean T1 bias of 3D MP2RAGE MRI from 2D inversion recovery was -23 msec ± 31 (P < .001). Conclusion Compared with three-dimensional (3D) dual-flip-angle techniques, 3D magnetization-prepared 2 rapid gradient-echo MRI enabled more accurate T1 mapping of hip cartilage, was less affected by B1 inhomogeneities, and showed high accuracy against a T1 reference in participants with hip pain. © RSNA, 2021.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste , Feminino , Gadolínio DTPA , Voluntários Saudáveis , Humanos , Masculino , Medição da Dor , Imagens de Fantasmas , Estudos Prospectivos
15.
AJR Am J Roentgenol ; 216(5): 1370-1377, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32783551

RESUMO

BACKGROUND. MRI use and the need for monitored anesthesia care (MAC) in children have increased. However, MAC is associated with examination delays, increased cost, and safety concerns. OBJECTIVE. The purpose of this study was to evaluate the success rate of nonsedated neuroradiologic MRI studies in children 1-7 years old and to investigate factors associated with success. METHODS. We retrospectively reviewed data from our institutional nonsedated MRI program. Inclusion criteria were outpatient nonsedated MRI referral, age 1-7 years old, and neuroradiologic indication. Exclusion criteria were MRI examinations for ventricular checks and contrast material use. Success was determined by reviewing the clinical MRI report. We recorded patient age and sex, type of MRI examination (brain, spine, craniospinal, head and neck, and brain with MRA), protocol length, presence of child life specialist, video goggle use, and MRI appointment time (routine daytime appointment or evening appointment). We used descriptive statistics to summarize patient demographics and clinical data and logistic regression models to evaluate predictors of success in the entire sample. Subset analyses were performed for children from 1 to < 3 years old and 3 to 7 years old. RESULTS. We analyzed 217 patients who underwent nonsedated MRI examinations (median age, 5.1 years). Overall success rate was 82.0% (n = 178). The success rates were 81.4% (n = 127) for brain, 90.3% (n = 28) for spine, 71.4% (n = 10) for craniospinal, 66.7% (n = 6) for head and neck, and 100% (n = 7) for brain with MRA. Age was significantly associated with success (odds ratio [OR], 1.33; p = .009). In children 1 to < 3 years old, none of the factors analyzed were significant predictors of success (all, p > .48). In children 3-7 years old, protocol duration (OR, 0.96; 95% CI, 0.93-0.99; p = .02) and video goggle use (OR, 6.38; 95% CI, 2.16-18.84; p = .001) were significantly associated with success. CONCLUSION. A multidisciplinary approach with age-appropriate resources enables a high success rate for nonsedated neuroradiologic MRI in children 1-7 years old. CLINICAL IMPACT. Using age as the primary criterion to determine the need for MAC may lead to overuse of these services. Dissemination of information regarding nonsedated MRI practice could reduce the rate of sedated MRI in young children.


Assuntos
Terapia Comportamental/métodos , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/psicologia , Neuroimagem/métodos , Cooperação do Paciente/psicologia , Jogos de Vídeo/psicologia , Fatores Etários , Encéfalo/diagnóstico por imagem , Encefalopatias/diagnóstico por imagem , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Cooperação do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Doenças da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Fatores de Tempo
16.
Radiology ; 296(2): 381-390, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32515680

RESUMO

Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement methods in terms of agreement, reproducibility, and reliability and to compare femoral torsion angles between the four different measurement methods. Materials and Methods This retrospective study evaluated patients with hip pain who underwent CT and 3-T MRI of the hip including sequences of the pelvis and distal condyles between May 2017 and June 2018. The four measurement methods differed regarding the landmark levels for the proximal femoral reference axis and included measurements at the level of the greater trochanter, femoral neck, base of the femoral neck, and level of the lesser trochanter. Intraclass correlation coefficients (ICCs) were calculated, and Bland-Altman analysis was performed. Results Forty-five patients (mean age ± standard deviation, 19 years ± 5; 27 female) and 57 hips were evaluated. Inter- and intrarater reliability were excellent for each of the four CT- and MRI-based measurement methods (ICC range, 0.97-0.99). Mean difference between CT- and MRI-based measurement ranged from 0.3° ± 3.4 (P = .58) to 2.1° ± 4.1 (P < .001). Differences between CT and MRI were within the corresponding ICC variation for all four measurement methods. Mean torsion angles were greater by 17.6° for CT and 18.7° for MRI (all P < .001) between the most proximal to the most distal measurement methods. Conclusion MRI- and CT-based femoral torsion measurements showed high agreement and comparable reliability and reproducibility but were dependent on the level of selected landmarks used to define the proximal reference axis. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Zoga in this issue.


Assuntos
Fêmur , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Feminino , Fêmur/anatomia & histologia , Fêmur/diagnóstico por imagem , Fêmur/fisiologia , Humanos , Masculino , Amplitude de Movimento Articular/fisiologia , Adulto Jovem
17.
Clin Orthop Relat Res ; 478(5): 1049-1059, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31977443

RESUMO

BACKGROUND: The diagnosis of slipped capital femoral epiphysis (SCFE) often is delayed. Although lack of clinical suspicion is the main cause of delayed diagnosis, typical radiographic changes may not be present during the initial phases of SCFE. The peritubercle lucency sign for follow-up of the contralateral hip in patients with unilateral SCFE may be beneficial in assisting the early diagnosis. However, the accuracy and reliability of this sign in patients with SCFE is unknown. QUESTIONS/PURPOSES: (1) What is the accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the peritubercle lucency sign on radiographs for the early diagnosis of SCFE compared with MRI as the gold standard? (2) What are the interobserver and intraobserver reliabilities of the peritubercle lucency sign on radiographs? METHODS: Between 2000 and 2017, 71 patients underwent MRI for an evaluation of pre-slip or a minimally displaced SCFE. Sixty percent of hips (43 of 71) had confirmed SCFE or pre-slip based on the presence of hip pain and MRI changes, and these patients underwent in situ pinning. Three independent experienced observers reviewed MR images of the 71 hips and agreed on the presence of a juxtaphyseal bright-fluid signal suggesting bone marrow edema in these 43 hips with SCFE, and absence MRI changes in the remaining 28 hips. The same three experienced observers and two inexperienced observers, including a general radiologist and an orthopaedic surgery resident, blindly assessed the radiographs for the presence or absence of the peritubercle lucency sign, without information about the diagnosis. Diagnostic accuracy measures including sensitivity, specificity, PPV, and NPV were evaluated. Intraobserver and interobserver agreements were calculated using kappa statistics. RESULTS: The overall accuracy of the peritubercle lucency sign on radiographs was 94% (95% CI 91 to 96), sensitivity was 97% (95% CI 95 to 99), specificity was 89% (95% CI 90 to 96), PPV was 93% (95% CI 90 to 96), and NPV was 95% (95% CI 92 to 99). All accuracy parameters were greater than 85% for the five observers, regardless of experience level. Intraobserver agreement was perfect (kappa 1.0), and interobserver agreement was excellent for the peritubercle lucency sign on radiographs across the five observers (kappa 0.81 [95% CI 0.73 to 0.88]). The reliability was excellent for experienced observers (kappa 0.88 [95% CI 0.74 to 1.00]) and substantial for inexperienced observers (kappa 0.70 [95% CI 0.46 to 0.93]), although no difference was found with the numbers available (p = 0.18). CONCLUSIONS: The peritubercle lucency sign on radiographs is accurate and reliable for the early diagnosis of SCFE compared with MRI as the gold standard. Improving the early diagnosis of SCFE may be possible with increased awareness, high clinical suspicion, and a scrutinized evaluation of radiographs including an assessment of the peritubercle lucency sign. LEVEL OF EVIDENCE: Level III, diagnostic study.


Assuntos
Articulação do Quadril/diagnóstico por imagem , Imageamento por Ressonância Magnética , Radiografia , Escorregamento das Epífises Proximais do Fêmur/diagnóstico por imagem , Adolescente , Criança , Diagnóstico Precoce , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Pediatr Radiol ; 49(12): 1669-1677, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31686172

RESUMO

Borderline acetabular dysplasia refers to mildly sub-normal patterns of acetabular shape and coverage that might predispose children to mechanical dysfunction and instability. Borderline dysplasia generally includes children with a lateral center edge angle (CEA) of 18-24°. Some children with borderline radiographic measurements have normal joint mechanics and function while others benefit from acetabular reorienting surgery. Although radiographic findings of borderline dysplasia might suggest instability, the ultimate diagnosis is based on history and physical exam in addition to imaging. Children with borderline acetabular dysplasia sometimes benefit from other cross-sectional imaging studies such as MR imaging to evaluate for secondary evidence of instability, including damage along the acetabular rim, or labral degeneration and hypertrophy. CT is also helpful for depiction of 3-D acetabular morphology for preoperative assessment and planning. Pediatric radiologists are often the first to identify borderline or mild dysplasia on radiographs. It is imperative that pediatric radiologists serve as effective consultants and offer appropriate recommendations as part of a cohesive multidisciplinary approach to this complex patient population.


Assuntos
Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/fisiopatologia , Adolescente , Fenômenos Biomecânicos , Criança , Articulação do Quadril , Humanos , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Radiografia/métodos , Amplitude de Movimento Articular/fisiologia , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X/métodos , Adulto Jovem
19.
Magn Reson Imaging Clin N Am ; 27(4): 721-735, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31575402

RESUMO

Fractures are common in children, although accurate diagnosis is confounded by mimics of fractures some of which are unique to the pediatric population. Such fracture mimics include developmental variations of the growth plates, normal anatomic structures that simulate fracture lines, and/or metabolic disorders that alter the pattern of ossification. Although subtle clues on plain radiographs may help to discriminate between a true fracture or injury and a fracture mimic, MR imaging may be helpful to eliminate uncertainty or expedite diagnosis.


Assuntos
Fraturas Ósseas/diagnóstico por imagem , Lâmina de Crescimento/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Radiografia/métodos , Criança , Pré-Escolar , Humanos
20.
Am J Sports Med ; 47(9): 2167-2173, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31233330

RESUMO

BACKGROUND: Osteochondritis dissecans (OCD) of the humeral trochlea is very rare. It may cause pain, mechanical symptoms, and loss of elbow motion, typically in the adolescent athlete. However, little published information is available regarding this condition. PURPOSE: To describe the clinical presentation, radiographic features, and prognosis of trochlear OCD. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: Over a 10-year period, 28 patients presented to a tertiary pediatric hospital with trochlear OCD. Medical records and imaging were analyzed to characterize presentation, lesions appearances, and outcomes. RESULTS: Mean ± SD age at presentation was 13.4 ± 1.6 years, and 13 of the 28 patients were male. The most common presenting symptom was pain (93%), followed by crepitus (54%). Evidence of trochlear OCD could be seen on initial radiographs in 94% of cases but was commonly missed. Coexisting capitellar OCD lesions were the most common associated abnormalities seen on magnetic resonance imaging (21%). Investigators noted 2 predominant patterns: "typical" trochlear OCD lesions (89%) were located on the lateral crista of the trochlea, 3.1 ± 4.4 mm lateral to the apex of the trochlear groove. This location corresponded to the medial tip of the capitellar epiphyseal ossification center and was not actually on the trochlear ossification center. "Atypical" trochlear OCD lesions (11%) were located more posteromedially. Trochlear OCD lesions in 4 elbows were managed surgically, while the remainder were managed nonoperatively. At mean ± SD follow-up of 13 ± 8 months, 12 patients (43%) were asymptomatic. A further 5 patients had ongoing crepitus but no pain (18%), and 4 patients (14%) underwent surgical treatment for their trochlear OCD (osteochondral fixation, n = 1; drilling/curettage, n = 3); 3 of the 4 patients experienced some improvement in pain. CONCLUSION: Although rare, trochlear OCD can cause considerable elbow problems. Clinicians should be aware of this differential diagnosis. Plain radiographs should be carefully scrutinized for subtle signs of trochlear OCD, particularly in the repetitive or overhead athlete with elbow pain. Although most patients' symptoms will improve with activity modification, some may require surgery.


Assuntos
Articulação do Cotovelo/diagnóstico por imagem , Úmero/diagnóstico por imagem , Osteocondrite Dissecante/diagnóstico por imagem , Adolescente , Artralgia/etiologia , Atletas , Cartilagem Articular/cirurgia , Criança , Articulação do Cotovelo/cirurgia , Epífises/patologia , Feminino , Humanos , Úmero/cirurgia , Imageamento por Ressonância Magnética , Masculino , Osteocondrite Dissecante/cirurgia , Dor/etiologia , Radiografia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA